16 Getting Started
2.6 System Alarm Board
The cPCIS-3320/AC features an embedded alarm board that
monitors temperature and fan status. Should a fan become dis-
abled or the temperature exceed 50
°C, the Alarm LED will light up
and an audible warning will be heard.
To disable the audible warning, press the Alarm RST button. The
Alarm LED will continue to flash until the fault is corrected.
The cPCIS-3320/M/AC features the optional Chassis Manage-
ment Module (CMM) that provides a remote management inter-
face for both chassis and board management. See Chapter 6 for
details.
Comments to this Manuals