Manual Rev. 2.00
Revision Date: January 28, 2005
Part No: 50-17019-100
PXIS-2680P
8-Slot 3U PXI
Portable Instrument Chassis with
300W+300W AC Power Supply
User’s Manual
Page view 0
1 2 3 4 5 6 ... 49 50

Summary of Contents

Page 1 - PXIS-2680P

Advance Technologies; Automate the World.Manual Rev. 2.00Revision Date: January 28, 2005Part No: 50-17019-100PXIS-2680P8-Slot 3U PXI Portable Inst

Page 2

2IntroductionThe PXIS-2680P includes a 15” SVGA LCD touch screen—anadditional monitor is not necessary. No additional LCD, touchpanel, or keyboard wir

Page 3 - Getting Service from ADLINK

Introduction 31.2 SpecificationsComplies with PXI Rev.2.2 specifications and accepts modulescompliant with CompactPCI, PICMG 2.0 specificationsElectr

Page 4

4IntroductionCoolingX Two 8cm, 12VDC ball bearing fans, 41CFM air flow/eachPhysicalX Number of PXI/CompactPCI slots: 8 (1 controller, 7 periph-erals)X

Page 5 - Table of Contents

Introduction 5ReliabilityX MTBF:Z Backplane: 800,000hrsZ Power Supply: 100,000hrs @ full load1.3 Mechanical Drawing and OutlineMechanical DrawingFigu

Page 6

6IntroductionOutlineFigure 1-3: PXIS-2680P Front Panel ViewFigure 1-4: PXIS-2680P Rear View

Page 7 - List of Tables

Introduction 7Figure 1-5: PXIS-2680P Left Hand Side ViewFigure 1-6: PXIS-2680P Right Hand Side View

Page 9 - 1 Introduction

Getting Started 92 Getting StartedIn this chapter, the unpacking procedure of the sub-system andhow to configure a portable PXI system is described.

Page 10 - 1.1 Features

10 Getting StartedFigure 2-1: System Controller Installation2. Push the handle until it clips in place. You will hear aclick sound when the handle has

Page 11 - 1.2 Specifications

Getting Started 113. Insert the controller board mounting screws and screwtightly.Figure 2-3: Mount the Controller Card with Screws4. When taking out

Page 12 - 4Introduction

Copyright 2005 ADLINK TECHNOLOGY INC.All Rights Reserved. The information in this document is subject to change without priornotice in order to improv

Page 13 - Mechanical Drawing

12 Getting StartedPeripheral Module Installation1. Smoothly slide the peripheral module into an availableperipheral slot. Make sure that the periphera

Page 14 - 6Introduction

Getting Started 13Removing and Installing a Power Supply1. Unscrew and remove the side panel.Figure 2-6: Removing the Power Supply (A)

Page 15 - Introduction 7

14 Getting Started2. Pull out the power supply while pressing.Figure 2-7: Removing the Power Supply (B)3. To replace, push and slide in the new.Figure

Page 16 - 8Introduction

Getting Started 152.3 Operation InstructionsHow to Release Keyboard and Touch PadThere are two release buttons located at the top-left and top-righto

Page 17 - 2 Getting Started

16 Getting StartedHow to Setup the KeyboardThe keyboard cable is located on the top portion of the keyboard;it is a coil cable with an RJ-45 connector

Page 18 - 10 Getting Started

Getting Started 17Keyboard PositioningThe keyboard angle can be adjusted by tilting the keyboard feetlocated at the bottom.Figure 2-11: Positioning t

Page 19 - Getting Started 11

18 Getting StartedLCD DisplayThe LCD display has a fixed mechanism. You can pull up the pairof feet at the bottom of the case to lift the LCD display

Page 20 - 12 Getting Started

Getting Started 19Figure 2-14: PXIS-2680P DVD-ROMCooling FansThe cooling fans are located at the rear of the chassis for easyaccess. There are two co

Page 21 - Getting Started 13

20 Getting Started2.4 Software InstallationTo enable the touch panel functionality, users need to first installthe driver into the system controller.

Page 22 - 14 Getting Started

Getting Started 21The LCD On/Off button turns the LCD on or off with each press.Figure 2-16: System Monitoring Panel Power LEDTemp. LEDAlarm reset bu

Page 23 - 2.3 Operation Instructions

Getting Service from ADLINKCustomer Satisfaction is top priority for ADLINK Technology Inc.Please contact us should you require any service or assista

Page 25 - Touchpad Operation

Backplane Overview 233 Backplane OverviewThe cBX-3008L backplane can accept both PXI compatible prod-ucts and standard CompactPCI products. The signa

Page 26 - DVD-ROM Drive

24 Backplane OverviewFigure 3-1: PXI Local Bus and Star Trigger RoutingLocal BusThe PXI backplane local bus of the cBX-3008L is a daisy-chainedbus tha

Page 27 - Cooling Fans

Backplane Overview 25asynchronous external events the system is monitoring or control-ling.System Reference ClockThe PXIS-2680P supplies the PXI 10MH

Page 28 - 2.6 System Monitoring

26 Backplane Overview3.2 Mechanical DrawingThe following figures show the two parts of the backplanes andmechanical drawing.Figure 3-2: cBX-3008L Fron

Page 29 - Getting Started 21

Backplane Overview 273.3 Pin AssignmentSystem ControllerPin Z A B C D E F25 GND +5V REQ64# ENUM# +3.3V +5V GND24 GND AD[1] +5V V(I/O) AD[0] ACK64# GN

Page 30 - 22 Getting Started

28 Backplane OverviewPin Z A B C D E F22 GNDPXI_BRSVA22 PXI_BRSVB22 PXI_BRSVC22 PXI_BRSVD22 PXI_BRSVE22GND21 GNDCLK6GNDNCNCNCGND20 GNDCLK5 GND NC GND

Page 31 - 3 Backplane Overview

Backplane Overview 29Star TriggerPin Z A B C D E F25 GND +5V REQ64# ENUM# +3.3V +5V GND24 GND AD[1] +5V V(I/O) AD[0] ACK64# GND23 GND +3.3V AD[4] AD[

Page 32 - Trigger Bus

30 Backplane OverviewPin Z A B C D E F22 GNDPXI_BRSVA22 PXI_BRSVB22 PXI_BRSVC22 PXI_BRSVD22 PXI_BRSVE22GND21 GNDPXI_LBR0 GND PXI_LBR1 PXI_LBR2 PXI_LBR

Page 33 - System Reference Clock

Backplane Overview 31General PeripheralPin Z A B C D E F25 GND +5V REQ64# ENUM# +3.3V +5V GND24 GND AD[1] +5V V(I/O) AD[0] ACK64# GND23 GND +3.3V AD[

Page 35 - 3.3 Pin Assignment

32 Backplane OverviewPin Z A B C D E F22 GNDPXI_BRSVA22 PXI_BRSVB22 PXI_BRSVC22 PXI_BRSVD22 PXI_BRSVE22GND21 GNDPXI_LBR0 GND PXI_LBR1 PXI_LBR2 PXI_LBR

Page 36

Backplane Overview 33Note: Please refer the following table for the routing of the Bus Mastering (REQ/GNT), IDSEL, PCI CLK, and Interrupt sig-nals.N

Page 37 - Star Trigger

34 Backplane Overview

Page 38

Troubleshooting and Maintenance 354 Troubleshooting and Maintenance4.1 TroubleshootingInstallation Issues: 1. Failure to power on is typically due to

Page 39 - General Peripheral

36 Troubleshooting and MaintenanceNo Display (LCD):1. Check that all the proper power up procedures has beentaken.2. Hook up an external CRT to the VG

Page 40

Troubleshooting and Maintenance 374.2 MaintenancePXIS-2680PYou should always make sure that the keyboard assembly is prop-erly attached onto the PXIS

Page 41

38 Troubleshooting and MaintenanceCleaning the LCD1. Do not use cleaners that contain alcohol.2. Do not use a cloth that could be abrasive to the surf

Page 42 - 34 Backplane Overview

Important Safety Instructions 39Important Safety InstructionsPlease read and follow all instructions marked on the product andin the documentation be

Page 43 - 4.1 Troubleshooting

40 Important Safety InstructionsX Openings in the case are provided for ventilation. Do notblock or cover these openings. Make sure there is adequates

Page 44 - DVD-ROM Failure:

Warranty Policy 41Warranty PolicyThank you for choosing ADLINK. To understand your rights andenjoy all the after-sales services we offer, please read

Page 45 - 4.2 Maintenance

Table of Contents iTable of ContentsTable of Contents... iList of Tables...

Page 46 - Cleaning the Keyboard

42 Warranty Policy3. Our repair service is not covered by ADLINK's two-yearguarantee in the following situations:X Damage caused by not following

Page 47 - Important Safety Instructions

ii Table of ContentsTrigger Bus ... 24System Reference Clock ...

Page 48

List of Tables iiiList of TablesTable 1-1: Electrical Output ... 3Table 3-1: JP2 and JP3 PXI

Page 49 - Warranty Policy

iv List of FiguresList of FiguresFigure 1-1: PXIS-2680P 3U PXI Portable Instrument Chassis ... 1Figure 1-2: PXIS-2680P Mechanical Drawing...

Page 50 - 42 Warranty Policy

Introduction 11 IntroductionADLINK PXIS-2680P is a highly integrated and fully mobile 3UPXI instrument chassis offering 8-slot capacity for modules.D